DRAC — Data Tables

A list of the different data sets available for use in DRAC:

  1. Radionuclide conversion factors: View, Download CSV
  2. Grain size attenuation factors for alpha dose rates: View, Download CSV
  3. Grain size attenuation factors for beta dose rates: View, Download CSV
  4. Etch depth attenuation factors: View, Download CSV
  5. Water content attenuation factors: View, Download CSV
  6. F, J and H parameters used for cosmic dose rate calculation: View, Download CSV
  7. Gamma dose scaling: View, Download CSV

1) Conversion factors

The alpha, beta and gamma dose (Gy.ka-1) produced per unit of the parent radionuclide: for 1 ppm U, 1 ppm Th, 1 ppm Rb and 1% K.

DRAC accepts radionuclide concentrations in ppm (U, Th, Rb) and % (K) only. Concentrations in other units, such as Bq.kg-1, should be converted to ppm/% prior to using DRAC.

AdamiecAitken1998Guerinetal2011Liritzisetal2013Cresswelletal2018
2.782.7952.7932.79
δUα0.01090.0110.0110.02
Thα0.7320.73750.73750.738
δThα0.00260.00260.00260.004
0.1460.14570.14590.142
δUβ0.00040.00040.00040.002
Thβ0.02730.02770.02750.028
δThβ0.00090.00090.00090.001
0.7820.79820.80110.835
δKβ0.00710.00730.00730.008
Rbβ0.000380.000370.000370.00037
δRbβ8.216E-68.0E-68.0E-68.0E-6
0.1130.11160.11180.112
δUγ0.00020.00020.00020.001
Thγ0.04760.04790.04810.0489
δThγ0.00020.00020.00020.0003
0.2430.24910.24980.248
δKγ0.00470.00480.00480.003

Download CSV ↑ Back to top

Full references for each of the datasets can be accessed via the References page.

We invite authors who calculate new and/or updated datasets for dose rate calculation to submit their datasets for use in DRAC. If you are interested, please contact us.